Smargo smartreader+ ( Dreambox/linux setup/howto)
Becouse the default manual is a bit crappy, herewith a manual to setup the smargo
smartreader+
first copy "srp_tools_x86" to a dir, i use /smargo
now go to that dir with telnet/ssh
#cd /smargo (enter)
Set the correct rights
#chmod 755 srp_tools_x86 (enter)
Check the options by issuing the help command
# ./srp_tools_x86 -h
Smartreader+ configtool v1.3
usage:
options:
-d (default comport = "/dev/ttyUSB0")
-p <0 = pc / 1 = dreambox>
-m <0 = autoswitch / 1 = fixed Mhz> mode
in fixed mode you can also apply:
-x
-t t = val
-e egt = val
Ok now some examples:
Set the reader to 8 Mhz fixed
# ./srp_tools_x86 -m 1 -x 6
smartreader+ version v1.3
MODE fixed
FREQ 8.00 Mhz
KERNEL normal
T_MODE t = 0
EGT 0
Set the reader to 5.33 Mhz fixed# ./srp_tools_x86 -m 1 -x 9
smartreader+ version v1.3
MODE fixed
FREQ 5.33 Mhz
KERNEL normal
T_MODE t = 0
EGT 0
Set the reader back to autoswitch mode
# ./srp_tools_x86 -m 0
smartreader+ version v1.3
MODE autoswitch
FREQ 5.33 Mhz
KERNEL normal
T_MODE t = 0
EGT 0
Ok set to autoswitch, even the frequency is still set to 5,33 Mhz the autoswitch will
override this settings and
choose from either 3,57 Mhz or 6 Mhz (t=0 or t=1 card)
READER VALUES - MHZ
3 - 16MHZ
4 - 12MHZ
5 - 9.61MHZ
6 - 8MHZ
7 - 6.86MHZ
8 - 6MHZ
9 - 5.34MHZ
10 - 4.80MHZ
11 - 4.36MHZ
12 - 4MHZ
13 - 3.69MHZ
14 - 3.43MHZ
15 - 3.20MHZ
On this way you can set the correct values for each reader.
When u use multiple readers don't forget the -d option to set the correct reader!
best frequency for seca canalsat:8 - 6mhz